JCI Annual Convention in CHIBA

Presentation information

B.Structural & Design » Seismic performance evaluation / Structural design & Design method / Vibration isolation

Structural design & Design method Ⅱ / Vibration isolation

Thu. Jul 16, 2015 1:00 PM - 3:15 PM Room 3 (2F 301)

[2004] EVALUATION METHOD FOR SHEAR CAPACITY OF TAPERED RC BEAMS WITHOUT SHEAR REINFORCEMENT

Chenwei HOU1, Koji MATSUMOTO2, Takayuki IWANAGA3, Junichiro NIWA4 (1.東京工業大学大学院理工学研究科土木工学専攻 2.東京工業大学Dept. of Civil Engineering 3.大成建設中国支店 4.東京工業大学理工学研究科土木工学専攻)

Keywords:Critical section, inclination of compressive strut, nonlinear FEM analysis, variable depth, 圧縮ストラット角度, 変動断面高さ, 耐力支配断面, 非線形FEM解析

This paper presents the evaluation method for shear capacity of tapered RC beams without stirrups. The nonlinear FEM analysis was found to be appropriate to simulate the shear behavior of tapered RC beams without stirrups. The simple relationship between the slope of taper and the inclination of the compressive strut was also proposed through FEM simulations. By determining the location of the critical section, the shear capacity of tapered RC beams without stirrups can be calculated. The calculated value showed good correspondence with the experimental results.