JCI Annual Convention in SAPPORO

Presentation information

The 41st JCI Technical Conference

B.Structural & Design » Structural analysis / Composite & Mixed structure

Structural analysis / Composite & Mixed structure Ⅰ

Wed. Jul 10, 2019 10:00 AM - 11:45 AM Room 8 (Meeting Room 206)

座長:内藤英樹(土木), 米澤健次(建築)

[2174] FEM解析による頭付きスタッドを用いたUFCスラブと鋼桁間の接合部のせん断耐力に関するパラメータ検討

Thi Thu Dung NGUYEN1, Toshimichi ICHINOMIYA2, Akinori SATO3, Takashi KOSAKA4 (1.Kajima Corporation, 2.鹿島建設, 3.Hanshin Express Co. Ltd., 4.阪神高速道路)

Keywords:shear capacity、 headed stud、 FEM analysis、 slab joint、 bridge、 optimization、せん断耐力、頭スタッド、FEM解析、床版の接合部、橋梁、最適化

In a hybrid bridge, the joint of UFC bridge slab and steel girder using headed stud shear connector and non-shrinkage mortar has been developed. Nevertheless, in the real structures, in order to adjust the elevation of the slab, the thickness of the filled mortar is varied, whereas, the shear capacity needs to be ensured. This paper presents a 3D FEM model, which simulated accurately the experimental results. Furthermore, results of a parametric study on shear capacity of the headed stud connection with different mortar thickness and stud height using 3D FEM analysis are reported.