コンクリート工学年次大会2019(札幌)

講演情報

第41回コンクリート工学講演会

B.構造・設計 » 構造解析/合成・混合構造

構造解析/合成・混合構造Ⅰ

2019年7月10日(水) 10:00 〜 11:45 第8会場 (206会議室)

座長:内藤英樹(土木), 米澤健次(建築)

[2174] Parametric Study on Shear Capacity of Joint between UFC slab and Steel Girder using Headed Studs by FEM Analysis

Thi Thu Dung NGUYEN1, 一宮利通2, Akinori SATO3, 小坂崇4 (1.Kajima Corporation, 2.鹿島建設, 3.Hanshin Express Co. Ltd., 4.阪神高速道路)

キーワード:shear capacity、 headed stud、 FEM analysis、 slab joint、 bridge、 optimization、せん断耐力、頭スタッド、FEM解析、床版の接合部、橋梁、最適化

In a hybrid bridge, the joint of UFC bridge slab and steel girder using headed stud shear connector and non-shrinkage mortar has been developed. Nevertheless, in the real structures, in order to adjust the elevation of the slab, the thickness of the filled mortar is varied, whereas, the shear capacity needs to be ensured. This paper presents a 3D FEM model, which simulated accurately the experimental results. Furthermore, results of a parametric study on shear capacity of the headed stud connection with different mortar thickness and stud height using 3D FEM analysis are reported.