9:45 AM - 10:00 AM
[14a-1C-4] Q factor enhancement of a carbon nanomechanical resonator by fluorine surface modification
Keywords:nanomechanical resonator,Q factor,Surface modification
In this study, Q factor improvement of carbon mechanical resonator was tried by surface modification using XeF2 gas. And also, the relationship between resonance, process condition of surface modification and surface condition of a carbon nanomechanical resonator was evaluated. As a result, increase in Q factor depended on the exposure time of XeF2 gas. And, we found that the Q factor improvement ratio was approximately 1.7 after 60-sec fluorination.