The 77th JSAP Autumn Meeting, 2016

Presentation information

Oral presentation

2 Ionizing Radiation » 2.2 Detection systems

[13p-B12-1~18] 2.2 Detection systems

Tue. Sep 13, 2016 1:00 PM - 6:00 PM B12 (Exhibition Hall)

Keitaro Hitomi(Tohoku Univ.), Keisuke Maehata(Kyushu Univ.), Toru Aoki(Shizuoka Univ.)

1:45 PM - 2:00 PM

[13p-B12-4] Development of hole-type MPGD with funnel-capillary plate

Ryutaro Ito1, Satoshi Ishizawa1, Fuyuki Tokanai1, Toru Moriya1, Hiroyuki Sugiyama2, Masahiro Hayashi2, Teruyuki Okada2, Haruyasu Kondo2, Takayuki Sumiyoshi3, Syunji Kishimoto4 (1.Yamagata Univ., 2.Hamamatsu Photonics, 3.Tokyo Metropolitan Univ., 4.KEK)

Keywords:micropattern gas detector, capillary plate, PMT

We have been developing a hole-type micropattern gas detector (MPGD) with glass capillary plate for digital X-ray radiography, cold neutron imaging, and gaseous photomultipliers (PMT) for the UV and visible spectral range. A new glass capillary plate (CP) has been developed for the hole-type MPGD. The developed CP has a funnel structure (funnel-CP) fabricated by utilizing a special manufacturing process for a standard CP. The open to surface area ratio is 90% for the funnel-CP. The higher ratio is expected to improve the collection efficiency of primary electrons created by the radiation because most of the electrons can enter the multiplication region without terminating on the upper CP electrode. Basic performance tests of the hole-type MPGD were carried out with X-ray beams for several gas mixtures based on Ne and Ar at 1 atm. We report on the characteristics of the novel hole-type MPGD with the funnel-CP.