The 64th JSAP Spring Meeting, 2017

Presentation information

Oral presentation

8 Plasma Electronics » 8.2 Plasma measurements and diagnostics

[15a-301-1~7] 8.2 Plasma measurements and diagnostics

Wed. Mar 15, 2017 9:00 AM - 10:45 AM 301 (301)

Kenji Ishikawa(Nagoya Univ.)

9:30 AM - 9:45 AM

[15a-301-3] Measurement of Water Vapor Density in Dielectric Barrier Discharge Plasma with Gas-Liquid Interface for Synthesizing Performic Acid

Kunihide Tachibana1, Toshihiro Nakamura1, Mitsuo Kawasaki2, Tatsuo Morita3 (1.Osaka Electro-Communication Univ., 2.Kyoto Univ., 3.PM Dimensions)

Keywords:dielectric barrier discharge, gas-water interface, water vapor density

We measured water vapor (H2O) density in dielectric barrier discharges (DBDs) with gas-water interface using tunable diode-laser absorption spectroscopy (TDLAS). The results show that the water vapor density is relatively larger in a water-shield DBD device, in which the gas-water interface is inverted, than in a normal DBD device. This fact is related to the higher concentration rattio of performic acid produced from CO2 and water in the former device.