The 80th JSAP Autumn Meeting 2019

Presentation information

Poster presentation

12 Organic Molecules and Bioelectronics » 12.7 Biomedical Engineering and Biochips

[19p-PB1-1~34] 12.7 Biomedical Engineering and Biochips

Thu. Sep 19, 2019 1:30 PM - 3:30 PM PB1 (PB)

1:30 PM - 3:30 PM

[19p-PB1-28] Modified Centrifugal Microfluidic Chip System with Reflow Capability for Single Cell Preparation

〇(PC)Wilfred Espulgar1, Masato Saito1, Shohei Koyama1, Hyota Takamatsu1, Atsushi Kumanogoh1, Eiichi Tamiya1 (1.Osaka University)

Keywords:microfluidics, single cell, reflow

A reflow system based on the reverse rotation of a centrifugal chip has been reported previously by our group. It allows the cell suspension to simply interact with the hydrodynamic traps several times which could provide a higher probability of trapping. This enables the decrease in the number of wasted cells in a suspension perfused through a typical microfluidic chip. Microfluidics technology has proven its usefulness in preparing single cells for Life Science Research. In our previous design, a trapping efficiency of 55% was obtained using THP-1 cells. Also, the minimum operation of the device was at 800 rpm that can be damaging or harmful to cells. With this in mind, the improved design was sought to be operated at lower rpm and with higher trapping efficiency.