The 80th JSAP Autumn Meeting 2019

Presentation information

Oral presentation

2 Ionizing Radiation » 2.3 Application, radiation generators, new technology

[20p-E305-1~7] 2.3 Application, radiation generators, new technology

Fri. Sep 20, 2019 1:45 PM - 3:30 PM E305 (E305)

Kenichi Watanabe(Nagoya Univ.)

2:00 PM - 2:15 PM

[20p-E305-2] Evaluation of photon counts of BL07A in NewSUBARU

Tomohiro Mishima1, Shuto Suzuki1, Shotaro Tanaka1, Kazuhiro Kanda1 (1.LASTI,UNIV.Hyogo)

Keywords:Synchrotron radiation, Soft X-ray, Beamline

Evaluation of photon counts of BL07A in NewSUBARU was performed. NewSUBARU light source facility was constructed for use of soft X-ray. BL07A was built for the experiments using high brilliance soft X-rays. The light source of BL07A is 3-m undulator. Undulator light was monochromatized using multi-layer mirror monochromator and some kinds of filters. Photon counts were measured by use of photo diode. In BL07A, high brilliance radiation experiment can be performed in the energy range of 80-800 eV.