10:00 AM - 10:15 AM
[12a-W833-1] Static Electricity of Insulating Flexible Intermediate BulK Container for Powder
-Effect of relative humidity on surface charge voltages-
Keywords:electrostatic charges, Flexible Intermediate Bulk Container, powder
Powder handling operations are conducted to support our daily life and industrial society. However, industrial accidents caused by electrostatic charges or/and discharges on powders are sometimes happened with an insulating flexible container. This paper reports surface voltages on a flexible container bag during power loading and unloading. Polypropylene pellets (PP, 2-3 mm, about 150 kg) was used as power sample. As a result, the maximum surface voltage exceed the 100 kV. And surface voltage decreased by increasing relative humidity.