Japan Society of Civil Engineers 2020 Annual Meeting

Presentation information

第I部門

地中構造物の耐震

Chair:Akihito Hata

[I-265] Vertical Support Performance of Reinforced Concrete Members and Frames with Shear Failure

〇Yoshinori Miyagawa1, Satoshi Komatsu1, Tatsumasa Watanabe1 (1.Central Research Institute of Electric Power Industry)

Keywords:Shear failure, Collapse, Buckling, Redundancy, Underground structure

Underground structures are statically indefinite and have the possibility to keep stability after the partial failure of members. Then, we have investigated the behavior to collapse to evaluate the above-mentioned redundancy. In this report the influence of out-of-plane shear reinforcement, the constraint by the surrounding ground and loading schedule was discussed through the experiment. Though the horizontal displacement at which the horizontal load capacity started to decrease was barely related with three factors, the resistance against collapse was superior in the case constrained with the sand or in the case of monotonic loading.

Please log in with your participant account.