16:45 〜 17:00
[D-3-02] Spatiotemporal Thermal Management of Homogeneous Oxide Sensor Array for Discrimination of Biomarkers in Mixed Molecules
Presentation style: On-site (in-person)
https://doi.org/10.7567/SSDM.2022.D-3-02
We propose a chemical sensor system for discrimination of trace-level biomarkers in mixed molecules based on spatiotemporal thermal management of homogeneous oxide sensor array. Self-Joule-heating modulates chemical reactivity of individual SnO2 channels, enabling a virtual heterogeneous chemical sensor array operation. Mixed molecules were separately transported to the sensor array via time-series desorption temperature control of silica adsorbents, which densify trace-level molecules in a sample gas. Furthermore, we demonstrate the discrimination of model samples which mimic urine of tumor patients using the proposed sensor system.
Abstract password authentication.
Password to download abstracts has been informed in the confirmation mail.