2018 Fall Meeting

Presentation information

Oral presentation

IV. Nuclear Plant Technologies » 403-1 Risk Assessment Technology, Application of Risk Information

[1P14-19] Fault Displacement PRA

Wed. Sep 5, 2018 4:25 PM - 6:00 PM Room P (E21 -E Building)

Chair:Hidemasa Yamano(JAEA)

5:25 PM - 5:40 PM

[1P18] Improvement of Fault Displacement PRA Methodology and Example of its Application to a Hypothetical NPP

(5) Example of Application of Fault Displacement Fragility Evaluation Methodology to a Hypothetical NPP

*Ryusuke Haraguchi1, Tetsuhiro Gou1, Kunihiko Sato2, Shinichi Yoshida3, Hideaki Tsutsumi4, Toshiaki Sakai4, Katsumi Ebisawa4 (1. Mitsubishi Heavy Industries, LTD., 2. MHI Nuclear Systems And Solution Engineering Co., Ltd, 3. OBAYASHI Corp., 4. Central Research Institute of Electric Power Industry)

Keywords:Fault Displacement PRA, Fragility

This paper shows consideration of respective median and uncertainties of realistic response and realistic capacity of SSCs which are necessary for the fault displacement fragility evaluation. And based on the fragility evaluation methodology presented in the last annual meeting, fragilities of SSCs of a hypothetical NPP are quantified. In addition, a procedure to develop a battery of input for the accident sequence evaluation is presented.