[3H13] Evaluation of the operation check and calibration methodfor the optical fiber type radiation monitor by using semiconductor laser

*Takahiro Tadokoro1, Shuichi Hatakeyama1, Katsunori Ueno1, Yuichiro Ueno1, Keisuke Sasaki2, Yoshinobu Sakakibara2, Toru Shibutani2, Takahiro Ito2, Koji Nehashi3, Mikio Koyama3 (1. Hitachi, Ltd. Reserch & Development Group, 2. Hitachi, Ltd., 3. Hitachi-GE Nuclear Energy, Ltd.)

Keywords:Nuclear Power Plant, Optical Fiber, Radiation Monitor, Long Wavelength Light-emitting Element, Semiconductor Laser, Operation Check, Calibration

現行軽水炉の過酷環境時における高温・高線量率環境下で、原子炉建屋及び原子炉格納容器の線量率を測定可能な光ファイバ型放射線モニタシステムの開発を進めている。2017年春の年会で、半導体レーザを用いた動作確認及び校正手法(O&M機能)の基礎検討結果を報告した。今回、O&M機能を実現するシステムを試作し、性能評価試験を実施したので、その結果を報告する。線量率測定用素子であるNd:YAGの発光波長と異なる808nmの波長の半導体レーザを用い、レーザ照射強度に対する計数率を測定した結果、7桁の範囲で、目標性能±0.4%F.S以内の精度での線形性、及び、モニタの放射線による劣化診断が可能であることを確認した。