[HTT16-P16] 環境標準試料の金属元素同位体測定
キーワード:標準物質、金属元素、同位体測定
In recent years, the development of analytical technics has made it possible to detect a limited variation of stable isotope ratios in metal elements. After that, many researchers had challenged and produced excellent results in this field, but the supply of primary reference materials for isotope measurement is limited.
To promote a stable isotope study related to the environmental research fields, RIHN has carried out high-precision isotope analysis using MC-ICP-MS for relatively abundant secondary environmental reference materials (ERMs).
For this research, I purchased 30 types of ERMs from NIST (National Institute of standard and technology, U.S.), JRC (European Commission's Joint Research Centre), and NMIJ(National Metrology Institute of Japan). These materials are not for isotopic analysis but certification of metal element concentration.
This presentation reports a data set of Mg-Zn-Fe stable isotope values and Sr-Pb-Nd radiogenic isotope ratios. This data set is a final version of earlier reports related to the isotopic analysis of environmental reference materials.
To promote a stable isotope study related to the environmental research fields, RIHN has carried out high-precision isotope analysis using MC-ICP-MS for relatively abundant secondary environmental reference materials (ERMs).
For this research, I purchased 30 types of ERMs from NIST (National Institute of standard and technology, U.S.), JRC (European Commission's Joint Research Centre), and NMIJ(National Metrology Institute of Japan). These materials are not for isotopic analysis but certification of metal element concentration.
This presentation reports a data set of Mg-Zn-Fe stable isotope values and Sr-Pb-Nd radiogenic isotope ratios. This data set is a final version of earlier reports related to the isotopic analysis of environmental reference materials.