1:00 PM - 1:15 PM
[9p-Z15-1] Gamma-Ray Irradiation Effects on CdTe Solar Cell Dosimeter
Keywords:CdTe, CdTe solar cell, II-VI compounds
In this work, compact and higly radiation-tolerant radiation dosimeter without voltage-bias application using solar cell such as CdTe is proposed for severe radiation environment near a nuclear reactor pressure vessel. First, gamma-ray tolerance of a CdTe solar cells was investigated. It was found that the CdTe solar cell has sufficient tolerance against gamma-ray exposure with greater than 3 MGy. It was demonstrated that gamma-ray induced current density increased linearly with increasing gamma-ray intensity in the range up to approximately 1.5 kGy/h. In addition, gamma-ray sensitivity was successfully increased by a stack of CdTe solar cells with parallel connection. Furhthermore, it was found that gamma rays with approximately 0.1 Gy/h was detected by the CdTe solar cells.