9:30 AM - 9:45 AM
△ [16a-B410-3] Influence of Cross-sectional Area of Gold Single Crystal Micro-cantilevers on Their Bending Strengths
Keywords:size effect, cross-sectional area, bending
The use of Au is proposed in order to increase MEMS accelerometer sensitivity. However, when Au material is used, the mechanical strength is a practical problem. Also, when metallic material is used in micro-scale, it’s necessary to consider sample size effect that the mechanical strength increases compared to bulk-scale. So, evaluating mechanical properties of Au material in micro-scale is important. This research reports influence of the cross-sectional area on the bending deformation of single crystal Au micro-cantilevers.