一般社団法人資源・素材学会 2022年度 春季大会

講演情報(2022年1月28日付 確定版)

企画講演

【企画講演/募集型企画】 粉体精製工学部門委員会「学生賞セッション」

2022年3月7日(月) 13:00 〜 16:50 第3会場 (Webex)

司会:芳賀一寿(秋田大学),晴山 渉(岩手大学),柴山 敦(秋田大学)

13:35 〜 13:50

[1K0306-15-03] (学生発表:博士課程) ICP-OESによる金鉱石中の金の微量分析

○メンドーサ ディエゴ1、笹木 圭子1 (1. 九州大学)

司会:芳賀一寿(秋田大学)

キーワード:湿式化学、金分析、高周波誘導結合プラズマ発光分光分析法、逆王水、金鉱石

Trace analysis by wet chemistry is inevitable to evaluate the gold grade in ores on a lab scale due to the limited sample amounts, while the fire assay is generally performed on an industrial scale. Gold (Au) is present as Au(0) in gold ores, especially encapsulated in sulfide grains of refractory gold ores, so aqua regia (3 HCl: 1 HNO3) is generally used for oxidation of Au(0) and complexation with Cl-. In addition, HF is necessary to digest the silicate minerals matrix that is often associated with sulfides. Generally, ICP-MS is a common measure for trace analysis in wet chemistry; however, “the memory effect” is known to diminish the accuracy of trace analysis for gold. Although the graphite furnace atomic absorption spectrometry (GF-AAS) is also used for trace analysis, it is known AuCl4- much reduces the absorbance. Therefore, the present work aims to establish the trace analysis of Au by inductively coupled plasma optical emission spectroscopy (ICP-OES). There are mainly two points to overcome. One is to examine the acid condition for stable digestion. Here, the different acid ratios of HCl and HNO3 were examined to digest three types of gold ore concentrates with different mineralogical matrices. Another point is to avoid the influence of the large signals derived from coexisting Fe in ore samples. In ICP-OES, the primal emission peak from Au is observed at 242.795 nm; however, it is markedly interfered by coexisting Fe signals at 242.836 nm, which is generally coexisting with large concentrations in the ore samples. The obtained results were verified by comparison with the results from fire assay. The established methodology was applied to several types of gold ores with different gold contents, with higher/lower Fe contents, with/without carbonaceous matter, with/without silver (Ag). The detection limit was estimated up to 20 ppb in the established method. This is basically useful for exploring the mineral processing of gold ores in lab scale research.

講演PDFファイルダウンロードパスワード認証

講演集に収録された講演PDFファイルのダウンロードにはパスワードが必要です。

現在有効なパスワードは、[資源・素材学会会員専用パスワード]です。
※[資源・素材学会会員専用パスワード]は【会員マイページ】にてご確認ください。(毎年1月に変更いたします。)

[資源・素材学会会員専用パスワード]を入力してください

パスワード