JCI Annual Convention 2025 in Morioka

Presentation information

The 47th JCI Technical Conference

B. Structural & Design » Framed structure/Structural Health Monitoring

Framed structure/Structural Health Monitoring

Thu. Jul 17, 2025 1:40 PM - 3:10 PM Room 10 (アイーナ5階 501B)

座長:浅井竜也(建築),稲葉紅子(土木)

[2173] CRITERIA FOR DETERMINING THE OPTIMAL SENSOR LAYOUT FOR IDENTIFYING BUILDING INELASTIC DEFORMATION MODE

Trevor Zhiqing YEOW (東京科学大学)

Keywords:Optimal sensor layout、Inelastic deformation mode classification、Structural health monitoring、Earthquake

For buildings with few accelerometers, the accelerometer layout should be able to account for various possible inelastic deformation modes (i.e., total-yield or soft-story). Two criteria are proposed for evaluating the suitability of an accelerometer layout: (i) maximum recorded floor displacements should vastly differ for different deformation modes, and (ii) the maximum representative building-level displacement should be accurately estimated. The application of these criteria was demonstrated using a case study of a 12-story building with different accelerometer layouts.